The paper "Design of Fire Protection Systems for Tall Buildings" discusses that the first priority for every designer must be the safety of life and should be protected at any cost. There are very few regulatory bodies and standard that directs the designer to have a fire-resistance construction…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER94.3% of users find it useful
Design of Fire Protection Systems for Tall Buildings
Read Text Preview

Extract of sample "Design of Fire Protection Systems for Tall Buildings"

Download file to see previous pages

The only reason that designer didn’t previously consider it as a potential threat was that the occurrence of these events is very less. But detailed studies after the WTC event have shown immense levels of flaws in the fire protection systems of tall buildings. The recent examples of fires resulting in complete collapse are WTC 1, 2, and 7.

Then the complete collapse of Apartment Block in St. Petersburg, Russia on June 3.2002, then Jackson Street apartments in Hamilton, Ontario, Canada on Feb 8, 2002. A list of collapses has been provided in Appendix 2 of all the collapse that was seen in the past. The concept of fireproof construction is that despite the complete burnout of the structure, the structure must not collapse at any cost. For this, two steps are taken by the standards and other implementation bodies.

Firstly the building should be resistant to fire for a certain level which is about 3 hrs, this is done to safeguard from the collapse of the structure, and secondly, an effective fire protection system should be in place, which is present for detection, fire fighting and effective evacuation of inhabitants. At present, the only International Building Code IBC 2006 solely has prescriptive fire resistance construction regulations and bounds the designer to follow it for the protection of structure against fire.

IBC is also supported by National Fire Protection Association and other similar organizations, which I have discussed in detail in later sections. The Approach of this report would be very similar to the process involved in designing a fire-resistant Tall building with an effective fire protection system. Characteristics of Tall Buildings As we are well aware of the processes through which the fire protection facility is brought into commission, where the first phase is the analysis and requirement determination of the fire protection, then the second is the design of these required systems, the third is the construction and finally the maintenance and operations of these systems.

Before the commencement of the design phase of a fire protection system the first and foremost step is to evaluate and analyze the building features and when it becomes detrimental to design a perfect system. What are the different categories of buildings and the types of construction? The first and basic categorization is based on a number of stories, under which a building that has more than 7 stories is declared a tall building. Then these tall buildings or high-rise buildings are subdivided into four property classes, where first is Apartment Buildings, second Hotels, Hospitals, and other facilities that care for the sick, and Office Buildings are the third and fourth type.

On the other hand, discrimination is made based on construction material. According to National Fire Protection Association, (NFPA 220, 2006) there are two basic types of construction: it either burns (combustible) or it does not (noncombustible). These types of construction can be further broken down into five categories. 

...Download file to see next pages Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Fire Report Essay Example | Topics and Well Written Essays - 4000 words”, n.d.)
Retrieved from https://studentshare.org/environmental-studies/1415617-fire-report
(Fire Report Essay Example | Topics and Well Written Essays - 4000 Words)
https://studentshare.org/environmental-studies/1415617-fire-report.
“Fire Report Essay Example | Topics and Well Written Essays - 4000 Words”, n.d. https://studentshare.org/environmental-studies/1415617-fire-report.
  • Cited: 0 times

CHECK THESE SAMPLES OF Design of Fire Protection Systems for Tall Buildings

Fire Protection Systems

Modern innovation can use cameras and computers to analyze the visual signs of fire and movement in applications inappropriate for or hostile to other detection methods (Greenman, 2003).... Strategically too, especially in high-rise buildings, depending on exact location of fire, different evaluation messages may be played on each floor to facilitate orderly evacuation and saving of lives (Jones, 2009).... In some fire alarm systems especially in high-rise buildings, arenas and other large facilities such as hospitals where total evacuation is difficult to achieve, emergency voice alarm communication systems (EVACS) are used....
7 Pages (1750 words) Research Paper

How Are the Good Designing and Fire Safety Connected in the Tall Buildings

The essay "How Are the Good Designing and Fire Safety Connected in the tall buildings?... tall buildings often symbolize the dominance and power of one country over another in respect of its varied architecture and a strong economy.... n terms of fire safety, a high rise building could be defined as a building taller than four stories or 75 feet simply because the aerial ladders of the fire department can barely reach up to that level.... The current trend to create taller buildings is a bid to reflect the impact of globalization on the development of the modern world....
10 Pages (2500 words) Essay

Analysis Fire Systems

All the floors except the ninth and the fifteenth had fire protection when this incident occurred.... aking the time when the building was constructed around the 1970s, there was a need to put many fire protection measures in the Spanish design code more so in the sprinkler works and the steelworks.... "Analysis Fire Systems" tries to identify four case studies of fire incidences in (Spain, U.... This would ensure in case of fire, the consequences would be less pronounced....
13 Pages (3250 words) Assignment

Fires, Building Materials, and Methods

he main works going on at the time were the creation of a cladding system made of aluminum, sprinkler system, boarding system fire protection to steel columns all around the building, and spray fire protection to steel beings in the inside of the building.... At the time of the fire, fire protection had been done for steelwork up to the 17th floor.... During those times those codes did not demand that a building should have steelwork fire protection as well as sprinkler fire protection in the entire building....
19 Pages (4750 words) Case Study

Ways BS 7974 in Enhancing Fire Safety in the Buildings and Structures

Moreover, the code of practice offers a foundation for the selection of suitable fire protection systems, as well as providing opportunities for inventive design.... BS 7974 also demonstrates the importance of considering the installation of fire detections and activation of fire control systems and alarms in order to maintain fire safety in buildings (Grimvall, Holmgren, and Jacobsson 2010).... Here, the code guides that all buildings should be designed and constructed to minimize the danger of fire....
12 Pages (3000 words) Term Paper

Pressurization and Ventilation, which is a Better Protection to High Rise Building Stairs

taircase pressurization systems, according to Ferreira and Cutonilli (2008), are popular methods of offering protection to exit staircases in tall buildings from smoke during an accidental fire.... The "Pressurization and Ventilation, which is a Better Protection to High Rise Building Stairs" paper presents a review of literature explored the various aspects of pressurization system and ventilation systems and their application in high-rise buildings.... According to Ferreira & Cutonilli (2008), the objective of existing design standards for the protection of staircases in high-rise buildings is to offer a 'smokeproof enclosure that prevents movement of smoke into the stairwell during a fire incident....
12 Pages (3000 words) Literature review

The Evacuation from High-Rise Building

This paper "The Evacuation from High-Rise Building" analyzes that tall constructions are distinctive from the view to their height from unadventurous lower edifices.... The unique fire safety matters that are related to tall structures can be recapitulated into six primary areas: accessibility of the fire department sections, movement of people through egress, natural forces, increase in people in the building and the fire load, amalgamation of occupancies, and the arrangement of domestic efficacy services....
24 Pages (6000 words) Research Proposal

Fire Protection Systems

From the paper "fire protection systems" it is clear that it would be better if the company used the residential sprinkler systems.... The project presents the technical report of the writer comparing two fire protection systems namely the residential sprinkler system and the residential water mist system.... 2015) when the fire protection systems are designed and implemented according to the British Standards they provide total protection of life and property in the residential area....
11 Pages (2750 words) Assignment
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us