StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...
Free

CT scanner justification - Essay Example

Cite this document
Summary
The demand for computerized tomography is on the rise now than ever. The current level of technology is a limitation to the provision of the service especially to the children. This is because small children have to be sedated before the diagnosis can be carried out. …
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER93.5% of users find it useful
CT scanner justification
Read Text Preview

Extract of sample "CT scanner justification"

The demand for computerized tomography is on the rise now than ever. The current level of technology isa limitation to the provision of the service especially to the children. This is because small children have to be sedated before the diagnosis can be carried out. Other than the enormous cost of sedation to the children, the current scanners, may expose the children patients to unnecessary radiation which has long term consequences. The machines also consume a vast deal of energy leading to high operation costs.

It is with this light that the radiology department wishes to propose the purchase of an advanced piece of equipment to facilitate the diagnosis. The Somatom Dual Definition Flash CT scanner from Siemens fits the current needs due to the technology used in its manufacture. Firstly, the machine reduces the conventional amount of radiation by a factor of up to 20. The conventional machines require between 8 and 10 millisievert in completing diagnosis. The new machine completes a similar diagnosis using a radiation of 1.

9 millisievert. This becomes possible through the use of two x-ray tubes which counter rotate simultaneously. The effect is enormous reduction of time for scanning. With this technology, a thoracic scan can be completed in 0.6 seconds. This implies that scanning proceeds without patients having to hold their breath. The machine, also, has Sinogram Affirmed Iterative Reconstruction (Safire) technology that allows for the interactive reconstruction of slice images. This system allows images of high quality to be achieved even when under movement.

This means that infants and young children can undergo a CT scan without being sedated and still achieve high quality imaging. In addition, the machine has dose reduction capabilities. The tube voltage should vary with the amount of radiation required and part of the body under scan. The conventional machines do not have a way of correlating the voltage requirement with the other scan parameters resulting to use of estimate values. The high voltage values result to excessive dosage or power loss.

With the proposed machine, a component called Care Kv recommends the voltage to use for the set radiation and other parameters adjust correspondingly. This way, the radiation dosage, reduces by up to 60%. Another feature is the Care child function. This enables scans to be taken for babies at lower Kilovolt values (70) in comparison to the 80-140 Kilovolt range used in conventional machines. This makes the machine safer than the present machines for children. Though the machine is more expensive than the conventional types, it carries with it a range of benefits that can be exploited to the hospital’s profitability.

The capital cost from a Siemens vendor is $ 390,291. This price range is competitive in comparison to that of other high performance machines like the Toshiba Aquillon 64 which costs around $ 400,000. However, the cost receives modulation due to the benefits in increasing the throughput of patients who require the CT scans. The manufacturers also give incentives to purchase the high cost machine. With its high speed, patients will not queue to receive the service. The power consumption will also be lower due to the various interventions aimed at reducing the voltage consumption.

The operation cost will, therefore, be low. In addition, the machine will create value for infants and babies who will not require sedation. Sedation costs increase the expenses on treatment. The low radiation values coupled with the accuracy will create confidence in the adjacent community encouraging them to undergo the diagnostics. The high radiation values reduce the willingness to undergo a CT scan due to the negative after effects of the test. Since no other hospital in the neighborhood has the technology, the facility, being a pioneer will receive scores of referral patients increasing the profitability.

It is with the view of the above advantages that a request for consideration in buying the capital equipment is made. The benefits offered by the expensive equipment easily outweigh the cost considering the role it will play in sensitive applications. Through increased treatments per day, and improved accessibility of children and infants to treatment, the return on investment is guaranteed making the investment worthwhile. References "medical news today." 30 may 2011. medicalnewstoday.com. 19 November 2011 . Casey, B. (2008, November 24).

Cardiac Imaging Digital Community. Retrieved November 19, 2011, from AuntMinnie.com : http://www.auntminnie.com

Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“CT scanner justification Essay Example | Topics and Well Written Essays - 500 words”, n.d.)
Retrieved from https://studentshare.org/finance-accounting/1584620-ct-scanner-justification
(CT Scanner Justification Essay Example | Topics and Well Written Essays - 500 Words)
https://studentshare.org/finance-accounting/1584620-ct-scanner-justification.
“CT Scanner Justification Essay Example | Topics and Well Written Essays - 500 Words”, n.d. https://studentshare.org/finance-accounting/1584620-ct-scanner-justification.
  • Cited: 0 times

CHECK THESE SAMPLES OF CT scanner justification

Safety Considerations in MRI

justification The project seeks to investigate risk and safety issues associated with MRI, establish safety issues to be considered in MRI and establish effects of MRI on human tissues and environment.... SAFETY CONSIDERATIONS IN MRI Name University Course Instructor Date Aim of the project Magnetic resonance imaging, as defined in various articles is a safe modality because; unlike X-ray systems, in MRI the ionizing radiation is nonexistent (not used)....
5 Pages (1250 words) Research Proposal

Using ICT When Presenting a Research Project

Information and Communication Technology (ICT) in the modern day scenario has increased its importance within the life of people.... The application of ICT has become a necessity with respect to the people's social as well as work periphery.... hellip; Using ICT When Presenting a Research Project It incorporates a range of software as well as hardware programs and devices including multimedia programs, camera, personal computers and database programs....
8 Pages (2000 words) Essay

Data Communication & Networking: Hotwire Pty Ltd

Some versions of photocopiers are of combined functions, having a photocopier, with an inbuilt printer and scanner of high qualities.... This case study "Data Communication & Networking: Hotwire Pty Ltd" presents the company that requires a bandwidth that can support its network for more than five years to come....
10 Pages (2500 words) Case Study

Computer Network Principles

The justification of the selected computing devices and the network equipments is required.... Helping students to navigate through the powerful and fastest growing world of information is a challenge.... The integration of computer networks in valuable for the students as well as the school management....
7 Pages (1750 words) Essay

4T MRI Knee Protocol at the Wesley Hospital in Australia

Computed Tomography (ct) provides effective analysis for categorizing fracture of the tibia plateau.... A significantly low percentage (10%) of the injuries recorded annually, were low-severity injuries, and serious non- fracture knee injuries also remain relatively rare, recorded at… Ligament tears form the large amount of serious non-fracture knee injuries at about 40%....
9 Pages (2250 words) Research Proposal

Cancellation of Contracts

Applying the general rule for the discharge of contracts, it may be noted that Boris has advertised one particular computer/printer/scanner, however, the goods that he has delivered do not correspond with the description of the all in one printer/scanner/copier that he has advertised....
8 Pages (2000 words) Essay

Computed Tomography Dosimetry and Dose Risks

The author state that Dual Energy ct (DECT) examinations yield medical benefits that must be balanced against potential risk from patient radiation exposure.... This has led to a rapid increase in using the ct scanners around the world.... In the United States alone, 62 million ct scans were performed in 2006, of which 4 million were for children (Brenner & Hall, 2007)....
10 Pages (2500 words) Research Paper

Library Information System Analysis

The paper 'Library Information System Analysis' is about Evergreen as the open-source software.... The license is according to GNU General public license version 2 or previous versions.... Consequently, it is free to download, alter, or disseminate to other people.... nbsp;… Further, it allows them to catalog, carry out efficient management and to disseminate these materials (Yang & Hofmann, 2013)....
6 Pages (1500 words) Case Study
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us