StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...

Steel Structures: Design and Behavior - Essay Example

Cite this document
Summary
"Steel Structures: Design and Behavior" paper argues that by reason of stability and economics, Scheme 1 would be recommended. Although more members are required, smaller members are to be used and hence, less expensive than Scheme 2. Smaller members would yield a higher ceiling height…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER95.7% of users find it useful
Steel Structures: Design and Behavior
Read Text Preview

Extract of sample "Steel Structures: Design and Behavior"

Download file to see previous pages

The roof beams are supported by the exterior main columns and are placed as a rafter. A truss is not included since a roof beam can carry the roof loads and also for the reason of abiding by the design intent of having a "high ceiling" and unobstructed natural light from the glazed section of the roof. The foundation is composed of isolated footings and retaining walls for the basement part. The longest span involved is 13 meters which is located at the facade of the building. Since the requirement is for the facade to be entirely composed of glass, two columns are supporting two roof beams propped against each other.

The load transfer is synonymous with that of an arch frame. The two columns are supported by a main beam at ground level and beams that connect it to the next span. If a huge lateral load or a very heavy roof load is applied way beyond the structure can support, these columns likely would be the first components to fail. No attachments are made to the existing museum and library, thus the new extension is structurally independent of them. Spans of 4.5 meters and 9 meters are designed for the beams wherein intermediate beams are provided for beams supporting a span of 9 meters.

This would yield smaller members in the subsequent analysis and design. Tie beams are also found in the foundation and ground floor framing to support lateral movements. Further, aside from beam-to-column connections, there are beam-to-beam connections as well, and a planted column supporting the stairs.3. Accommodation of ServicesBuilding services are accommodated and are given 0.8 meters. For services located in the basement, ground floor, and first floor; there is enough space for the conveyance of building utilities and at the same time, their pipe runs can be concealed.

However, cladding must be made at the 1st floor overhead utilities (e.g. lighting), since there is no ceiling on the 1st floor.C. Scheme 2:1. Functional FramingScheme 2 is designed to have the least number of structural members as possible. The advantage to this approach is fewer members and longer spans that would give to larger uninterrupted spaces. However, members would have to be bigger or deeper to support longer spans. The framing for the basement remains the same as in the previous scheme.

The framing support for the ground floor is remarkably decreased. This is for the reason that tie beams have been eliminated considering that the ground floor slab would be slab-on-fill. A wall footing tie beam is designated as support for the admin office wall. For the first-floor framing, only one intermediate beam is designated for the slab at the adult's reading area. The span of 9 meters on the side of the cavity wall side is supported by two columns only. The roof framing is the same as in the scheme. 

...Download file to see next pages Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Library extension Essay Example | Topics and Well Written Essays - 1250 words”, n.d.)
Library extension Essay Example | Topics and Well Written Essays - 1250 words. Retrieved from https://studentshare.org/miscellaneous/1531363-library-extension
(Library Extension Essay Example | Topics and Well Written Essays - 1250 Words)
Library Extension Essay Example | Topics and Well Written Essays - 1250 Words. https://studentshare.org/miscellaneous/1531363-library-extension.
“Library Extension Essay Example | Topics and Well Written Essays - 1250 Words”, n.d. https://studentshare.org/miscellaneous/1531363-library-extension.
  • Cited: 0 times

CHECK THESE SAMPLES OF Steel Structures: Design and Behavior

Design Proposal for a Visitor Center

The essay "design Proposal for a Visitor Center" focuses on the critical analysis of the major issues in the design proposal for a visitor center.... The structural design must have column-free spaces in lecture rooms and exhibition areas.... First, it must provide structural framing suitable for sloping and wet terrain with fluctuating water levels up to 6....
2 Pages (500 words) Essay

Structural design 1

he structure engineer has to critically evaluate and analyze different materials and their behavior when loaded and select the most effective and affordable materials.... Proper structural design must be done before erecting a house to ensure that after construction the columns and beams will be able to support the load imposed on these structural members.... Failure to carry out proper structural design results to the building being too weak and it may collapse killing many people (Charlton, 1973)....
13 Pages (3250 words) Essay

Weathering Steel - Advantages and Disadvantages

lthough weathering steel provides enough benefits to justify its selection as a construction material for use in massive steel structures, yet certain factors need to be considered while evaluating its utility.... Weathering steel is not the right option for the construction of bridges or high rise steel structures in such areas.... The most distinguishing characteristic feature of weathering steel is its anti-corrosive behavior exhibited through a self rusting procedure that is a byproduct of the unique nature of oxidization it undergoes, which is quite different to that experienced by unalloyed forms of steel....
8 Pages (2000 words) Research Paper

The Process of Steal-Making

Stronger and better steel structures and equipment can be manufactured through fabrication procedures such as rolling, shearing, blanking and welding.... lane Stress behavior Plane Strain behavior ... Effects of Stress on Pitting Corrosion behavior of Low-Carbon Steel.... efore the fabrication of steel for the manufacture of engineering and structures, a design must be in place.... Figure II shows a chart of the design process....
8 Pages (2000 words) Essay

Steel Structure: Cutty Sark, MaryRose Museum and Titanic Museum

steel structures design are guided by codes and standards which offer benchmark design considerations.... he evaluated steel designs offer valuable lessons for future consideration of steel structure design and construction.... Economic considerations also largely feature in steel structure design and involve comparison of costs and materials.... steel structures literature Steel structure: Cutty Sark, MaryRose museum and Titanic museum steel structures remain pivotal to design of major structures across the globe....
7 Pages (1750 words) Case Study

Different Types of Loads and Forces Which Act on Structures Throughout Its Life Cycle

Loads are the core of the design and analysis has to be done on the loads.... Field testing and instrumentation are important for steel structures.... Although bridges are designed within conservative limits based on the codes, the assumptions made like the composite behavior and the support conditions usually have some underestimation of the capacity of the bridge to bear loads.... Minimum design loadings have to be specified within building codes so as to allow for some reduction in load bearing walls, designing columns, piers supports as well as foundations. ...
6 Pages (1500 words) Report

Aspects of Fire Behaviour

design Analysis Procedure For Failure Modes, Effects and Criticality Analysis (FMECA).... Code of practice for fire resistant design 59(5):8-23... It also seeks to identify different types of failure modes occurring in structures and signs of collapse and its hazard in construction. ... According to Serah (2003), if steal structures do experience collapse due to exposing them in extreme temperatures, the collapse will remain localized only to that area that experienced the high temperatures....
5 Pages (1250 words) Article

Materials Used for Structural Purposes

This occurs due to excessive loading, the use of defective building materials, poor design and/or geometry, and poor workmanship.... This occurs due to excessive loading, use of defective building materials, poor design and/or geometry and poor workmanship. ... Creep is an indication of temperature and stress considerations that have to be taken into account when estimating the deformation behaviour and the strength of steel structures under fire conditions (Chalivendra & Bo Song, 2012). ...
7 Pages (1750 words) Assignment
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us