The paper "Boiling Liquid Expanding Vapor Explosion" highlights that it is essential to state that July 5th, 1973 gave rise to a drastic BLEVE incident in Kingman, Arizona. This incident killed 11 firemen. BLEVE means Boiling Liquid Expanding Vapor Explosion…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER94.2% of users find it useful
Boiling Liquid Expanding Vapor Explosion
Read Text Preview

Extract of sample "Boiling Liquid Expanding Vapor Explosion"

A leak was identified and endeavors to correct the defect by striking the fitting with a large wrench triggered the gas to ignite, which turned the tank car into a blowtorch. Processes that are linked to BLEVE include heat transfer (from the flame to tank, between liquids and vapor phases, and from tank walls to the liquid and vapor stages, thermodynamic changes within the tank linked with pressure buildup, tank failure, material property degradation, and activation of the pressure relief valve. Thus, issues with a missing relief valve, poor maintenance, inaccurate instruments, and inoperative or bypassed safety devices are linked with BLEVEs (Laboureur et al., 2013).

Most cases of BLEVEs are conveyed by fragmentation, blast effects, and fireball radiation. A BLEVE leads to the spontaneous, vigorous liquid boiling and the production of a shock wave. This is a type of explosion that occurs in a vessel under a rapid heating process containing a high degree of pressurized liquid, for example, liquefied petroleum gas that has failed catastrophically. This substance (e.g. propane) is stored under pressure and contains a boiling point below the ambient temperature range. In the case where the liquid contains a temperature above ambient boiling points, but it is heated before it is emitted by an external heat source to a temperature exceeding its boiling point can result in a BLEVE.

This means that when the vessel fails, the internal pressure drops drastically to atmospheric and the hot liquid rapidly boils releasing a lot of vapors. This damage is a result, of a pressure wave from the rapid expansion of the emitted vapor and flying fragments of the vessel and piping; if the material is combustible a hazard takes place. The hazard brought about by a BLEVE of a container containing flammable liquid is a fireball, a major fire, and the production of a powerful radiant heat flux. Moreover, BLEVE can be employed to refer to any sudden loss of containment of liquid more than its normal boiling point at the time of its failure. This can be accompanied by fragmentation of the vessel, and if the liquid is flammable, then a fireball or vapor cloud explosion is expected (National Fire Protection Association & International Association of Arson Investigators, 2005).
A container or vessel can fail for several reasons mostly damaged by the mechanical impact of another object.

This damage results in the development of a brutal force affecting the internal pressure which creates a crack if the container material is brittle. Therefore, if the container is faced with the impact of any means, it may rupture completely resulting in BLEVE. Other reasons for a container or vessel failure are corrosion, internal overheating, and manufacturing defects which can make the container’s metal weaken beyond the degree to which it can withstand internal pressure and cause large cracks, and in some cases completely separate the container into pieces. In addition, if a vessel or container is exposed to an external fire source below its design pressure point, BLEVE may occur if the vapor space is exposed to flames. This is because the flames heat and weaken the metal leading to its failure.

A precaution all plant employees have to keep in mind is to expect and be ready for a BLEVE in case there is a fire outbreak. All protective safety systems must be well maintained to enhance safety. Most importantly, water spray fire protection systems i.e. fire water monitor nozzles provide protection against BLEVE as they keep the vessels cool thus maintaining mechanical integrity when exposed to a heat source (Laboureur et al., 2013). In reference to the Kingman incident, standard procedures for handling a BLEVE became well-known in all fire departments nationally. Films and pictures of this incident form part of the training course. Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Paraphrasing 2 Essay Example | Topics and Well Written Essays - 500 words”, n.d.)
Paraphrasing 2 Essay Example | Topics and Well Written Essays - 500 words. Retrieved from https://studentshare.org/miscellaneous/1652461-paraphrasing-2
(Paraphrasing 2 Essay Example | Topics and Well Written Essays - 500 Words)
Paraphrasing 2 Essay Example | Topics and Well Written Essays - 500 Words. https://studentshare.org/miscellaneous/1652461-paraphrasing-2.
“Paraphrasing 2 Essay Example | Topics and Well Written Essays - 500 Words”, n.d. https://studentshare.org/miscellaneous/1652461-paraphrasing-2.
  • Cited: 0 times

CHECK THESE SAMPLES OF Boiling Liquid Expanding Vapor Explosion

U05a1 Case Analysis

A possibility of ‘Boiling Liquid Expanding Vapor Explosion (BLEVE) could not be ruled out, which could mean total destruction of the city.... As early as in 1985, the possibility of a great disaster in case of an explosion inside the tunnel was pointed out by ‘The Baltimore Sun'....
4 Pages (1000 words) Case Study

The BLEVE Accident at Kingman

efore a BLEVE (Boiling Liquid Expanding Vapor Explosion) incident occurs, the fire grows to dangerous heights.... The event happened as a result of an explosion, created through a leak that had formed in the valves of a railroad car.... With an expansion in the amount of pressure that had been building up in the railroad car, there was an explosion that was felt by everyone who was within a radius of a little over eight kilometers.... The immediate impact was felt by the firefighters who were stationed near the site of the explosion....
2 Pages (500 words) Essay

Introduction to Combustion and Fire

The paper "Introduction to Combustion and Fire" discusses that the various zone models are primarily used for rooms or buildings that are rectangular in shape and have ceilings that are smooth, flat and horizontal.... It is advantageous because it helps us to understand the type of fire.... ... ... ...
9 Pages (2250 words) Assignment

Introduction to Combustion and Fire

This study considers qualitatively Semenov diagram for a thermal explosion in a vessel with cold.... Also, the study explains the effect of initial temperature and size of the vessel on the critical conditions for the thermal explosion to be possible.... walls.... ...
17 Pages (4250 words) Case Study

Free Atoms and Radicals

Analyze thermal explosion in adiabatic conditions and the mechanism of the self-accelerating reaction.... However, if the adiabatic temperature rise is sufficient to trigger undesired reactions, it can lead to a thermal explosion.... This assignment "Free Atoms and Radicals" discusses the atom as the smallest indivisible particle that has an independent existence....
8 Pages (2000 words) Assignment

Fire and Explosion Investigations

This assignment "Fire and explosion Investigations" discusses an analysis of thermal explosion in adiabatic conditions and the mechanism of the self-accelerating reaction.... The assignment explains the effect of the initial temperature and size of the vessel for a thermal explosion to be possible....
13 Pages (3250 words) Assignment

Introduction to Combustion and Fire

This assignment "Introduction to Combustion and Fire" discusses combustible liquids and solids and fire in enclosures.... The formation of a hot spot is a necessary element for ignition to occur.... A hot plate generates that hot spot by localizing the electrical energy in one spot.... ... ... ... This assignment "Introduction to Combustion and Fire" discusses combustible liquids and solids and fire in enclosures....
10 Pages (2500 words) Assignment

The November 2005 Buncefield Oil Storage Incident

echanism of fuel-air explosionFuel-air explosion, a type of BLEVE (Boiling Liquid Expanding Vapor Explosion) normally results when the ignition of a gas-cloud occurs in a confined volume (Advisory Group report 2007:2).... The Buncefield oil cloud explosion incident occurred at 06:02:32 Hours on Sunday, eleventh, December 2005 through a series of fuel-cloud explosions (Buncefield MIIB 2005:5-7).... Oil specialists on BBC NEWS indicated the incident was caused by a fuel-air explosion following the failure of the 'leak detection system' to detect fuel leakage resulting in the build-up of explosible fuel concentration in bunds and dense vapor-cloud formed due to frost conditions at ground level....
11 Pages (2750 words) Case Study
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us