Image contrast is normally described as proton density: T1-weighted or T2-weighted

Fat has a rapid T1 recovery time, and hence the T1 time of fat is short. Water, however, takes much longer to recover, and the T1 time of water, therefore, is long. In order to achieve maximum contrast between fat and water, it is advisable to make the selected TR shorter in order for the tissue to regain the longitudinal magnetization and the subsequent RF pulses are affected by the partial saturation. This makes the fat vector gain more longitudinal magnetization as compared to water and create fat to appear brighter on the T1weighted image. T2 weighted image After the RF pulses are applied to the spins, the spin interaction appears. This causes the T2 to decay due to the nuclei interaction in the magnetic fields in the region. This also reduces the transverse magnetization. It is also imperative to note that the water and the fat have varying T2 decay. This is mainly caused by the rapid exchange of energy. The fat have very short T2 TIME, on the other hand, the processing of water has very long T2 TIME DUE TO ITS INEFICINCY. The TE is responsible for controlling the amount of decay (T2) appearing before the reception of the signals. Therefore to acquire a very clear difference between the water and the fat, it is advisable to increase TE and TR. ...
On the other hand, there are tissues that have a lot of proton contents. These classes of tissues include the brain and are manually characterised by high ability to of creating a high. The proton density and the T2 images can be easily acquired in a single sequence (double echo). This process uses the long TR and short TE. The first echo is achieved by use of the long TR and the short TE, while the second echo is achieved by long TE and long TR to acquire the T2 weighted images. Proton density is just a representation if the number of hydrogen atoms that are in the tissue, for example, the CSF contains higher proton density as compared to the bone. For the proton density that occurs, it is important to reduce the impact of the T1 weighting imaging and THE T2 weighting imaging through making the TR longer and TE shorter (McRobbie 2007). b) Describe how images proton density, T1-weighted or T2-weighted contrast, plus T2* contrast, are acquired with gradient echo pulse sequences. The flip angle of the gradient echo pulse sequence is adjusted over a range of close to 80m degrees to get a larger tip angle in order to acquire more T1 weighting to the formed image; this will also give a smaller tip angle to provide more T2 and T2* weighting to the so formed images. Proton density images On the other hand, the proton density images can be acquired by the use of low flip angles and fast image acquisition, short TR and TE times. T1 weighted images This can only acquired by the GE pulse sequence through the use of mid range pulse angles, short TR and TE times. The flip angles are enlarged (70 -110 degrees), the TE are shortened (5-10 ms) and the TR approximately less than 50 ms T2 weighted images This is acquired with the GE through mid-range pulse angles with ...Show more

Summary

T1 and T2 Name: Course Tutor: Institution Department: Date: Assignment Questions Q1: Image contrast is normally described as proton density, T1-weighted or T2-weighted. a) Describe how images with the three different types of contrast are acquired with spin echo pulse sequences…
Author : vincenzo42
Image contrast is normally described as proton density: T1-weighted or T2-weighted essay example
Read Text Preview
Save Your Time for More Important Things
Let us write or edit the essay on your topic
"Image contrast is normally described as proton density: T1-weighted or T2-weighted"
with a personal 20% discount.
Grab the best paper

Check these samples - they also fit your topic

Diffusion weighted (DW) Magnetic Resonance Imaging MRI
Achievement of Different Diffusion Weightings 11 IV. Diffusion Information- Measurement 11 References 13 I. Introduction This paper discusses diffusion in general, and diffusion in the context of its use in magnetic resonance imaging or MRI. It discusses the use of diffusion in different MRI methods, with a focus on diffusion-weighted MRI.
13 pages (3250 words) Essay
Exogenous and Endogenous Tracers in Perfusion-Weighted Imaging
In this technique, blood parameters (haemodynamic quantities) such as blood volume, blood flow, and the average time taken by a tracer molecule to traverse the tissue (mean transit time) can be assayed using exogenous tracers such as gadolinium or endogenous tracers such as arterial blood.
7 pages (1750 words) Essay
Perfusion-weighted imaging (PW) MRI (magnetic resonance imaging)
The amalgamation of both practices is tremendously encouraging for the primary recognition and valuation of stroke, for tumour description and for the estimation of neurodegenerative illnesses (Nelson, et al., 1995). Perfusion applications are intended to evaluate the distribution of blood to a vascular bed.
12 pages (3000 words) Essay
Estimation of Weighted Average Cost of Capital
To increase the shareholders' wealth and firm's value in the market, it must have a capital structure which protects the interest of all stakeholders. Such a capital structure is known as the optimum/optimal capital structure. The present paper describes and analyses the capital structure Proton and find how an optimum capital structure is formed.
2 pages (500 words) Essay
The Weighted Average Cost of Capital
As more and more debts are attained, the cost advantage of debt over equity makes the weighted average cost of capital decrease until the point when more of cheaper funds and less of expensive equity funds are used. After this point, both the cost of debt and cost of equity start to increase hence the weighted average cost increases.
3 pages (750 words) Essay
Weighted-average cost of capital and capital structure
On the one hand companies are trying to gain valuable support from the respective governments; while on the other hand, all efforts are being made to do away with undue expenditures, and making the capital structure optimal in efficiency.
4 pages (1000 words) Essay
Weighted Average Cost of Capital (WACC)
Diagnostics India Limited, is principally involved in the manufacturing, marketing and servicing diagnostics products that provide effective ways to assist in the diagnosis, monitoring and management of disease; and (2) Merge Healthcare Incorporation (formerly known as Merge
5 pages (1250 words) Essay
Weighted Application Blank Scoring System
of related characteristics, specify item response categories, assign them weights, prepare the application blanks, decide on a cutoff point for selection and finally administer them to subjects to test their validity and reliability (Dawson et al., 1984, 120). Of course the real
1 pages (250 words) Essay
Image contrast is normally described as proton density, T1-weighted or T2-weighted
Fat has a rapid T1 recovery time, and hence the T1 time of fat is short. Water, however, takes much longer to recover, and the T1 time of water, therefore, is long. In order to achieve maximum contrast between fat and water, it is advisable to make
3 pages (750 words) Essay
Proton exchange membrane fuel cells
A major factor which has impacted ob the invention of fuel cells is environmental concern. Important to note is the growing concern for better and safer environment for human health. In this
20 pages (5000 words) Essay
Hire a pro to write
a paper under your requirements!
Win a special DISCOUNT!
Put in your e-mail and click the button with your lucky finger
Your email
YOUR PRIZE:
Apply my DISCOUNT
Comments (0)
Click to create a comment
Contact Us