We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Nobody downloaded yet

Jamar Dynamometer - Assignment Example

Comments (0) Cite this document
Summary
The background of the progression of strength assessment tools replicates the past of the vocation that have industrialized as well as utilized them. The chronology of their expansion moreover explains the course as well as the tribulations stumbled upon with their variations, a number of which are still applicable…
Download paper
GRAB THE BEST PAPER
Jamar Dynamometer
Read TextPreview

Extract of sample
Jamar Dynamometer

William A. Hammond MD sought after lifting up the condition of neurologists on top of that of universal practitioners, partially by the utilization of complicated tools like that of the handgrip dynamometer in addition to dynamograph. The community who invented these machines was time and again the individuals who utilized them, like that of the Dr. John Harvey Kellogg, Dr. William Hammond and Sir Francis Galton. There is limited information in relation to early on potency evaluation tools. a large number of the prehistoric writings have been mislaid throughout the wars in which the libraries have been damaged, like that of the library within Alexandria, which at its climax around 330 B.C. is alleged to have infatuated more than 700,000 papyrus rolls .
The main objective of this assignment is to be able to create a document containing details regarding the assessment of grip strength using a Jamar Dynamometer as a standardized tool and Manual Muscle Strength as a non-standardized tool.
Lately the American Society of Hand Therapists signified that a consistent arm positioning for hand strength tests, accomplished that the position of the upper limit may manipulate measurements, moreover suggested that the patient ought to be sitting with his shoulder objectively revolved, elbow bend at 90' plus the forearm with wrist in neutral position. While checking the capricious of wrist position, (RW, 1990) established no important variation in grip strength by test positions at 0' also 15' ulnar variation, 0' with 15' dorsiflexion, or else whichever grouping of these. The Jamar dynamometer had the maximum calibration accurateness of all the instruments checked. In most of the cases the arm ought to not be sustained by the inspector or else by a support. For grip strength determination, the dynamometer is placed vertically also in stripe with the forearm to preserve the typical forearm also wrist positions. For reliability, the handle of Jamar dynamometer is fixed at the second handle position 3.8 cm for all the subjects.
The protocol:
To reduce the influences of the body position upon grip strength assessments, the normal protocol recommended by the American Society of Hand Therapists was utilized. With reference to them, a subject must be sitting within a straight backside chair with no arm rests amid the feet flat on the flooring, the shoulder within a neutral rotation as well as flexion. The elbow ought to be contracted to 900 by the forearm also wrist within neutral position. The protocol for the management of the dynamometer in the estimation of the grip strength together with the description of how to formulate the finest utilization of the calculated indexes, for experimental documentation functions together with ... Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Jamar Dynamometer Assignment Example | Topics and Well Written Essays - 3250 words”, n.d.)
Retrieved from https://studentshare.net/science/299265-jamar-dynamometer
(Jamar Dynamometer Assignment Example | Topics and Well Written Essays - 3250 Words)
https://studentshare.net/science/299265-jamar-dynamometer.
“Jamar Dynamometer Assignment Example | Topics and Well Written Essays - 3250 Words”, n.d. https://studentshare.net/science/299265-jamar-dynamometer.
  • Cited: 0 times
Comments (0)
Click to create a comment
CHECK THESE SAMPLES - THEY ALSO FIT YOUR TOPIC
A Better Marker than BMI for BMD in African-American Women
The BMC and BMD in grams per unit projected area were measured at the lumbar spine, the hip (femoral neck, greater trochanter, intertrochanter), and the whole body using Hologic QDR-2000by a specially licensed and certified technician. Fat mass and lean body mass (LBM) were determined by dual energy x-ray absorptiometry (DXA).
3 Pages(750 words)Lab Report
Paraphrase
mber of prior conditions – lower limb injuries, neurological disorders, heart disease, degenerative joint disease, or vestibular or neuromuscular disorders. There is some question as to the screening process, however, because the process used to recruit and verify
3 Pages(750 words)Essay
Rebort asimant
Compressor is used for adiabatic compression, the combustion chamber is used to add heat to air at constant pressure, the turbine is used for adiabatic expansion; take work from the air and use it in running the compressor, the nozzle
6 Pages(1500 words)Research Paper
Development of mathematical model to calculate fuel consumption of passenger cars
The world population is 6.5 billion at the moment and rising. Climate change has caused widespread greenhouse effects like global warming, higher acid levels in oceans and reduced ice cover at the poles (Harrabin, 2013). The major causes of greenhouse effect are the by-products of industrialization, and especially carbon dioxide (Samimi & Zarinabadi, 2011).
3 Pages(750 words)Essay
Air-turbine performance
An example of such a gas-stream driven machine is an air-turbine. The output of work during the conversion process may be measured and then compared with the amount of energy that is extracted from the airstream over a range of turbine shaft
5 Pages(1250 words)Coursework
Chapter 7
Differing testing needs and the sizable variety of engines makes standardized testing difficult. The current study examined the fuel consumption of passenger vehicles by both laboratory testing and real life driving in order to arrive at a mathematical model that could be
8 Pages(2000 words)Literature review
Organizing PhD Thesis
A chief cause of environmental degradation is exhaust emissions from vehicles, especially passenger cars. This paper attempts to quantify the relationship between vehicle fuel emissions and the various factors that contribute to it such as speed,
18 Pages(4500 words)Literature review
Two stage compressor
having the appropriate effect towards the plant performance especially the stage effect of cooling and the polytropic intercooling compression index and the compression work. Air compressors have been in existence for well over 50 years. They have as many applications as there
4 Pages(1000 words)Lab Report
Lab
The results recorded were used to calculate for the derived values such that torque was obtained as 72.7 N/M and ranges between 72.1 N/M - 72.7 N/M, the brake power was obtained to be in the range 40987.46667 KW - 8370.193333 KW, the brake thermal efficiency was
2 Pages(500 words)Lab Report
Refrigeration Laboratory
ed under three main categories: heat pump heat capacity and coefficient of performance, compressor power before and after inverter and inverter loss versus the frequency of the compressor. It was noted the optimal intermediate temperature increased correspondingly with increase
8 Pages(2000 words)Lab Report
Let us find you another Assignment on topic Jamar Dynamometer for FREE!
Contact us:
+16312120006
Contact Us Now
FREE Mobile Apps:
  • About StudentShare
  • Testimonials
  • FAQ
  • Blog
  • Free Essays
  • New Essays
  • Essays
  • The Newest Essay Topics
  • Index samples by all dates
Join us:
Contact Us