Summary
The author of the "Outputs in a Control Circuit" paper argues that outputs in a control circuit involve the outcome of the whole circuit. Examples of outputs include a lamp, an LED, a buzzer, a piezo, stepper motor, relay, solenoid, and a seven-segment display. …
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER92.9% of users find it useful
Outputs in a Control Circuit
Read Text Preview

Extract of sample "Outputs in a Control Circuit"

Control A control circuit is a form of circuit that utilizes the control devices in determining when the loads would be energized, and de-energized through the control of the current flow. The circuits do carry minimum voltages in comparison to the power circuits. In a control circuit, inputs are whatever sets the circuit in action. Examples of inputs include a switch, keypad, thermistor, light dependent resistor, photodiode, opto-isolator, phototransmitor, and reed switch. On the other hand, outputs in a control circuit involve the outcome of the whole circuit. Examples of outputs include a lamp, an LED, a buzzer, a piezo, stepper motor, relay, solenoid, and a seven-segment display. PLC control circuit A PLC circuit has numerous terminals for interpreting the low and the high states of logic from switches to sensors. It has a number of output terminal, in which the output low and high signals the lighting of power, contractors, solenoids, other devices, and small motors that lead themselves to an off and on control. In order to make a PLC simple to be programmed, their language of programming was made to be similar to the logic diagrams of the ladder logical diagrams. The PLC have been reported as being industrial computers hence their inputs together with the outputs signals are characterized by 120 AC voltage similar to the electromechanical relay control that they normally replace. Even though the PLC do have the potential of inputting and outputting the signal of low-level DC of not the used magnitude, this may be exceptional yet not the rule. Programming and signal connection standards could be varied between PLC models, but may be similar to give room for the PLC generic introduction. Figure 1 displays a simple PLC appearing from the front view. The two terminal screw give out the connection of about 120 AC voltage used in powering the internal circuitry PLC that is labeled L2 and L1. The displayed figure shows six terminal screw from the left side that give connection towards the inputted devices in which the terminals represent different input channels having an X label. A lower left terminal screw is identified as a common connection connected to a L2 of approximately 120 VAC power source. Figure 1 In the housing of PLC, there is an opto-isolator device that is connected between the terminal input and common terminals. This device or the Light-Emitting Diode (LED) gives electrically delinked high logic signals of the circuitry computer whenever there exist a120 VAC applied power in the respective terminal input and the similar terminal. An LED that is indicated on the front panel of the PLC provides some visual indication of an input that is energized. Figure 2. In this regard, the PLC would be in a position to interface together with the real devices of the world like solenoids. The real logic in the control system is made in the PLC through the computer program. The program is responsible in dictating the type of output that becomes energized in whatever conditions of input. Even though the program happens to be a diagram of logic ladder with relay and switch symbol, there exist no actual switch that operate inside the PLC to establish logic relationships on the outputs and the inputs. They are coils and imaginary contacts. The program is normally entered and observed through a personal connected computer to the programming port of PLC. Figure 3 shows a PLC program and a circuit. Figure 3. Whenever the pushbutton is unactuated, there will be no power sent towards the X1 PLC input. The shown program displays an open x1 contact arranged in series with a Y1 coil. There would be no power directed to the Y1 coil hence the output of PLC Y1 will remain de-energized, and the lamp indicator that is linked to it would remain dark. When the pushbutton is pressed, the power is directed to the PLC’s x 1 input. Any and all the x1 contacts seen in the program assumes the actuated state in a similar manner to a case where the actuated relay is contacted by the relay energized coil referred to as X1. This means that energizing the X1input would result into the normally open x1 contact similar to the sending power of the Y1 coil. Once the Y1 coil of the energized program (the real Y1) becomes energized, the lamp connected to it would be lit. This is shown in figure 4. Figure 4. It is should be understood that Y1 coil, X1 contact, connecting wires and the ‘power” appearing the display of a computer were all virtual. The aforementioned components exist as commands within a computer program. It is fundamentally a piece of software resembling a real relay schematic diagram. It is vital to understand that the personalized computers are utilized in displaying the PLC’s program and may not be for the continued operation of PLC. After loading the PLC program from a computer that is personal, the personal computer would be unplugged off the PLC making it to continue following the commands that are programmed. One main merit of the implementation of the logic control software instead of the hardware is the fact that the inputted signals need to be reused many times within the program (Pessen, 2008). Pneumatic systems involve the systems that are used in compressing the air to control and transmit energy. The Pneumatic systems are normally utilized in making the train doors be controlled, production automation, and in mechanical clamps. In our case, the compressor system would be responsible in compressing the needed pressure. It would be converting the from the mechanical energy engines and motor into the compressed potential energy. The single compressor could supply different components that compress the air that is moved in the pipes from the pneumatic parts. When the pressured is inputted in the control pressure port P, the spool would shift to the left making the inlet be connected to P and the B passage. The other working passage A will give an air release through R2 and R1 hence the directional valve would be in an operational direction up to when the signals are contrary received. The type of control valve would be said to function and have the memory. References Pessen, D., 2008. Industrial automation. New York: John and Willey press. Read More
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us