StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...
Free

Investigation of Fire Safety in CA Lawson Building - Report Example

Cite this document
Summary
This report "Investigation of Fire Safety in CA Lawson Building" discusses the Lawson building that was a single-story building with an area of about 4480 ft2. Just like any investigation about fire, it was essential to establish a timeline of happenings and establish the fuel load in the building…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER91.2% of users find it useful

Extract of sample "Investigation of Fire Safety in CA Lawson Building"

Name Tutor Course Date Report about the Investigation into Fire Safety: C.A. Lawson Building Incident Overview Fire occurred on the night of January 22nd, 2012, at the C.A. Lawson building in De Pere. The company was holding a night party within its premises and the performing artists had utilized pyrotechnics that caused the ignition of foam insulation lining the walls as well as component of the ceiling of the stage. The news camera video operator who was there during the time of fire, it spread very fast all over the building. Smoke was visible from the doorways and the windows as well within a very short time. In addition, flames were seen breaking via a portion of the roof within less than ten minutes. Egress from the building where the occasion was being held was hampered by crowding at the building’s main entrance. Many people were injured but no one during the fire incident. This report is going to provide an analysis of the likely technical causes of the building failure that resulted to the fire. The Lawson building was a single-story building with an area of about 4480 ft2. Just like any investigation about fire, it was essential to establish timeline of happenings and establish the fuel load in the building, in terms of material category, quantity in addition to location. Evacuation The area fire service contained the fire and evacuated everybody who was in the building. Approximately ten minutes after ignition, the fire service had evacuated everybody and started to flow water in the region of the front door. Activities at the company were shut down and staff and people evacuated as firefighters worked. Impact of the Fire There was no one who died since the area fire departments worked jointly to control the fire at the C.A. Lawson building. C.A. Lawson building Company’s administration estimated damage and loss at $100,000. The property in the building was damaged by the fire since fire officers managed to salvage a few properties from the building. Nevertheless, the staffs carrying out the evacuation process were not injured. In addition, the smoke emitted due to the fire break out as well as the waste from the fire remains may have had negative environmental impacts. Development and Spread of the Fire The timeline was established from the video footage that had been taken during the fire, interviews from the eyewitnesses as well as records from the area fire departments. The video and also post-visit of the site gave information regarding the fuel load. The fire started accidentally and the mobile monitoring agency raised the alarm which informed the fire service regarding the fire incident. About 40 seconds after ignition, people started evacuating. At 45 seconds after the fire explosion, the fire alarm rang, and the fire spreading. The camera operator left the building at 80 seconds following the fire break out, and smoke was flowing out of the front doorway. After about five minutes after the fire breakout, individuals were heaped within the doorway. Individuals evacuated to the extent possible using the available doorways, broken. People were still being helped out through the main bar room windows at 10 minutes following the ignition. Just about 12 minutes after the fire breakout, fire came out of the front of the building. Seconds afterward, the fire department arrived and started flowing water within the area of the front door. The first ten minutes of the fire was the aim for the stimulation of fire. The form and also composition of materials established as being in the building were typified as basically flexible polyurethane foam, ceiling tiles, in addition to an industrial pyrotechnic device. Photographs that had been taken before the fire break out were utilized in determining the quantity and site of the fuels that made up the interior finish of the building. The materials analysis carried didn’t consist of any materials essentially recovered from the building that caught fire. Technical Approach to the Stimulations To come up with a practical Fire Dynamic Simulator (FDS), several important physical experiments were carried out. Instrumentation The analysis room was outfitted with thermocouples, heat flux gauges in addition to extraction probes for measuring CO, CO2, O2 and also hydrogen cyanide. Additionally, there was installation of fixed temperatures along with rate-of-rise heat sensors and also sprinklers. At the beginning of the analysis, there was no water supply for the sprinklers but the sprinklers were supervised constantly for the time to activation. Tenability Criteria Generally, a room turns out to be untenable for individuals when any of the following state takes place: Temperature goes beyond 120°C The heat flux goes beyond 2.5 kW/m2 The volume of oxygen fraction decreases below 12% These levels give principles in general acknowledged by the fire protection engineering profession as resulting into fast incapacitation, but might be tolerated for a short but otherwise unspecified duration. Hydrogen as well as CO characterizes major risks for human beings (Moodie 32). Vents & Openings All four sides were modeled as open to the external environment for allowing air entrance and exit of combustion products. The external temperature was presumed to be similar to the initial internal temperature and it was also assumed that the wind was calm. The four vents that were producing heat modeling the pyrotechnic devices released energy for 45 seconds, starting at t = 0 seconds. Temperature Temperature slices were assessed to evaluate the tenability circumstances that were present during the development of fire. Horizontal slice were obtained at the 1.5m and the 0.6m levels above the floor, and the ceiling was rendered transparent to assess the distribution of the temperature throughout the building as a whole. This examination used 120 °C as the temperature tenability threshold. The noteworthy variations within temperature between the 1.5m elevation as well as 0.6m take place within the main entrance and the windows. This region is tenable at the lower level because of the inflow of fresh air via the open windows as well as the open doorway. Oxygen volume fraction concentrations were also assessed within the stimulation for examining the tenability circumstances that were present during the fire evolution. Horizontal slices were obtained at the 1.5m and also 0.6m levels for assessing the building as a whole. The examination utilized a volume fraction of 12% as the O2 tenability threshold. Basing on the oxygen limit, the building occupant would have had less than five minutes of tenable state. Tenability subsists for the longest period within the main door region. At such a lower level, it is evident that there is no likelihood of tenability in any other region apart from the main door entrance. The open windows in the building establish a more tenable environment. This was the safest area for the building occupants before the evacuation. Because of the open door and windows around this area, the stimulation shows that adequate fresh air entered in the building to sustain a height of tenability with respect to oxygen within the regions bordering the open windows as well as the main door. This trend is indicated to be constant through the stimulation end since the recordings illustrate that people were trying to get through the main door five minutes after the ignition. This is consistent with the projected oxygen concentration near the main door. Stimulation of Full Building Equipped with Sprinklers Another stimulation of the full building was performed for examining the impact that sprinklers might have had on the fire as well as the environment. The contribution from the FDS occurrence stimulation was joined with the sprinkler contribution from the FDS sprinklered total replicate simulation. Three sprinklers were positioned within the stimulation. One sprinkler was placed at the center of the alcove while the others were positioned using 3.4 m spacing. Whereas the acceptable sprinkler spacing could have been higher than 3.4 m throughout the building, the alcove would need a sprinkler in spite of the sprinkler utilized throughout the rest of the building. In the cases where there are no sprinklers, flashover of the alcove altered the tempo of vulnerability enlargement considerably. The alcove sprinkler was indicated to prevent flashover within the sprinklered investigations as well as the stimulations, considerably lessened the fire hazard. Oxygen Oxygen volume fractions were assessed within the sprinklered stimulation in order to examine the tenability state that was there over the fire evolution. Horizontal slices were obtained at the 1.5m height whereby there was removal of the roof to assess the entire structure. This examination used a volume portion of 12% as the O2 tenability threshold. Basing on 12% O2 tenability, the environment was tenable over the entire stimulation period. Recommendations Basing on the results of the investigations, several recommendations have been proposed that are targeting at enhancing life safety within residences. Some of the major recommendations that would require changes to the national standard building codes consist of: Materials that are highly flammable should be clearly identifiable and be specifically banned as an interior finish material within all building All the buildings to be installed with an automatic fire sprinkler system The other recommendations that tackle critically required research to act as the foundation for further developments within codes and practices include: Better understanding of human behaviors during disaster circumstances and to project the effect of building design on safe egress within urgent situations Better understanding of fire spread and suppression The council ought to "withdraw" the C.A. Lawson's environmental permit until the company effectively deals with the negative environmental effects resulting from the fire incident. Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(Investigation of Fire Safety in CA Lawson Building Report, n.d.)
Investigation of Fire Safety in CA Lawson Building Report. https://studentshare.org/engineering-and-construction/2047072-report-about-the-investigation-into-a-fire-safety
(Investigation of Fire Safety in CA Lawson Building Report)
Investigation of Fire Safety in CA Lawson Building Report. https://studentshare.org/engineering-and-construction/2047072-report-about-the-investigation-into-a-fire-safety.
“Investigation of Fire Safety in CA Lawson Building Report”. https://studentshare.org/engineering-and-construction/2047072-report-about-the-investigation-into-a-fire-safety.
  • Cited: 0 times

CHECK THESE SAMPLES OF Investigation of Fire Safety in CA Lawson Building

Training in Fire Safety

However, it is a common mistake to assume that only firefighters bear the responsibility of fire safety; each of us is responsible for our own safety.... As is often observed, it is best to be trained at preventing/ averting fire at an individual level simply because the society and government may take time to reach and react; whereas if precautions are taken by the individual he/she is in a better equipped to face any inevitable consequences of fire and/or avert them....
5 Pages (1250 words) Research Paper

Criminal investigation

An act of arson is perpetrated whenever, any wilful or malicious burning or attempt to burn, with or without intent to defraud, of a dwelling house, a public building, a motor vehicle, or aircraft, personal property of another, etc, takes place.... By statute arson has been greatly enlarged and it is extended to the burning of any barn or uthouse having hay or grain therein; any barrack, rick or stack of hay, grain, or bark; any public building, church or meeting-house, college, school or library....
5 Pages (1250 words) Essay

Criminal Investigation

Direction of fire.... Direction of fire.... During the preliminary investigation of arson, it is necessary to survey the surroundings in order to establish if there are any factors, such as forced entry, that infer arson.... Criminal investigations What are the main things to remember in the preliminary investigation of a suspected arson?... During the preliminary investigation of arson, it is necessary to survey the surroundings in order to establish if there are any factors, such as forced entry, that infer arson....
1 Pages (250 words) Essay

Fire service administration

Minimum requirementsThe NFPA via a document, the standard requirements for the investigation of fire, states minimum requirements for an investigator.... Just around the same time the janitor noticed the fire and alerted the housekeepers to alert the department of fire.... He also said that he had been setting a series of fire in apartment buildings in the neighborhood.... Significant changes in safety regulations of fire in schools were established nationwide....
2 Pages (500 words) Essay

Fire service administration

Certain connecting evidence that includes the investigation of insured history, operability of fire extinguisher, burglar detection system in place and how the insured came to know about the fire, are essential for investigation (Redsicker & O'Connor, 2010).... A Probable Cause Affidavit should contain many aspects such as when and where the incidence took place; relevant information should be in chronological order leading to the ending point of ample evidence for a particular location; if other investigator need to investigate the place of incidence, it requires the following conditionality and in order to ensure maximum effectiveness, it should be with the consensus of all the stakeholders; Investigators are duty bound to keep that cause of fire for examination later on; the mentioned laws allow sharing of information between the police and fire investigator besides the investigators of the insurance company (Davis, 1978)....
2 Pages (500 words) Essay

Building Fire Systems

one pressurizationThe settingup of high pressure compartments in the rooms (zones) adjacent to the compartments of fire or smoke origin.... one pressurizationThe settingup of high pressure compartments in the rooms (zones) adjacent to the compartments of fire or smoke origin.... Depending on the level of fire protection and control mechanism that the building stakeholders agree, the number pressurized zones can vary from one compartment to the maximum number of adjacent compartments....
6 Pages (1500 words) Essay
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us