StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...
Free

Japanese Earthquake and Tsunami: Fukushima - Research Paper Example

Cite this document
Summary
This paper “Japanese Earthquake and Tsunami: Fukushima” will briefly examine the terribly Fukushima accident and examine three aspects of that accident on how they relate to the UK’s nuclear safety measures and regulations. One of the aspects will be further be examined…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER98% of users find it useful
Japanese Earthquake and Tsunami: Fukushima
Read Text Preview

Extract of sample "Japanese Earthquake and Tsunami: Fukushima"

Japanese Earthquake and Tsunami: Fukushima Introduction The nuclear plants at Fukushima are Boiling Water Reactors (BWR), and they generate electricity through boiling water and rotating a turbine with steam from the boiling water. As explained by Okimoto et al. (2011) the nuclear fuel is used to heat the water to create steam, and the steam drives turbines, which generate the electricity. The steam is later cooled and condensed again to water; the process starts again as the water heated by the nuclear fuel to generate steam. The reactor works at nearly 285 Celsius degrees. This paper will briefly examine the terribly Fukushima accident and examine three aspects of that accident on how they relate to the UK’s nuclear safety measures and regulations. One of the aspect will be further be examined. Analysis of events at Fukushima on March 12, 2011 This section gives an overview of the main facts of Fukushima incident. The earthquake that occurred in Japan on that date was more times greater than the worst earthquake the nuclear plant was prepared for. For instance, the earthquake was 8.9 on Richter scale, while the nuclear plant was built to sustain a maximum of 8.2; this means that the earthquake was 5 times more of what was prepared for (Okimoto et al., 2011). When the earthquake happened, all the nuclear reactors at the Fukushima plant automatically went off. Within a few second following the earthquake, the control rods were inserted in the core, which stopped the nuclear chain reaction. At this moment, the NISA (2011) notes that cooling system was to take away the residual heat; this is about 7% of total power heat load on normal operation. However, this was not a normal operation. The earthquake damaged the external power supply of the Fukushima nuclear reactor. This was a difficult accident for any nuclear plant, and such incident is referred as “loss of offsite power.” A nuclear reactor and its backup system is built to manage this kind of an accident by using the backup power system to maintain the operations of the coolant pumps. More so, because the plant went off, it could not generate any electricity. For a period of one hour, the several installed emergency diesel power generators went on and provided the required electricity. Nonetheless, when the tsunami (a rare and larger one) happened, it caused floods to the diesel generators and made them to fail (TEPCO press release (2011). A fundamental aspect of all nuclear power plant structure is “defense in depth.” This aspect results in engineers designing nuclear plants that can resist harsh disasters, even in case of various systems failing. A big tsunami that damages all diesel generators at the same time is also anticipated; however the tsunami that happened that day was not expected at all. Upon the failure of diesel generators, the operators switched on emergency battery powers. However the battery power was designed to last for only 8 hours and after this, the plant operators began emergency operations (TEPCO press release, 2011). The emergency measures taken included starting water injection, they started with seawater and the freshwater that was injected into reactor main circuits. This was meant to stop the fuel melt down that could occur in such a case. Owing to the fact that the plant had lost most of its cooling capabilities the operators had to employ whatever cooling option they had to stop the heat. Though, we may not know every aspect of the accident, there is enough information to determine three aspects in nuclear Safety case being used in UK. The following section will discuss these three aspects. 1. Control and containment of combustible gases As a requirement for design, the production of combustible gases in a nuclear plant has to be reduced in normal operations and even during fault situations. Though high radiation fields’ produces hydrogen from radiolysis of water, the amounts are normally small and under ordinary conditions, the levels of the gases released are comparatively safely managed within the plant. But, very high amounts can be generated during an accident, for example zirconium fuel generation and steam on loss cooling in BWR nuclear cores. According to World Nuclear Association (2011) provision for such case should be developed in BWR, as designed in the PWR. However, gas-cooled nuclear reactors do not generate hydrogen in this manner. In the situation of the Fukushima, there are some arguments that the paths for ventilation of gases from the reactor, maybe, were not updated in accordance to increase global knowledge regarding the possible outcomes of venting in BWR accident situations. Though, not all is known about the specific design aspect of Fukushima-1 reactor, it is possible that shortcomings in venting paths could have worsened the situation, particularly in the destructive explosions that occurred in reactor I and 3. More so it seems that an explosion happened in the suppression pool of reactor 2, probably infringing the primary containment. This could show that a lot of attention ought to be been focused more on the design as well as safety evaluation of the safety of Fukushima reactors. 2. Spent fuel strategies A complicating aspect in the Fukushima incident was the spent fuel kept on the site, specifically in fuel pond in the reactor buildings. for example in reactor unit 4 pond, it is said that there were more than two and half cores that were more than 1,331 of spent fuel kept in the pond that were built close to the reactor. More so, about 6,000 spent fuel elements were kept in the in the main storage pond located on the site, additional quantities of the fuel elements were put in dry storage casks. However, according to Office for Nuclear Regulation (2011), these facilities on the site do not seem to have worsened or contributed to the problems that occurred in Fukushima nuclear plant. Spent fuel ponds in the reactor building forced the operators to employ increased packing density of spent fuel elements because of reduced spare capability in the ponds. Prior to the operators increasing the packing density in the spent fuel pond, they made a lot of consideration regarding the accident as well as the cooling abilities of fuel ponds. This is because increased packing density shortens the available time following the loss of cooling accident, before the boiling of the fuel pond. This thus puts a lot of onus on the dependability of the cooling systems of the reactor and on operator corrective action. 3. Cooling supplies The situations that resulted in this accident were such that new and untested way of supplying coolant in the reactors and the affected fuel ponds were necessary for a number of weeks. According to Office for Nuclear Regualtion (2011a) this led in numerous of tones of contaminated water being amassed on the site with some water leaking into the sea, while some of the water were discharged by the operators to the sea to free tank capacity. In the duration some other cooling could be employed at the Fukushima- 1 reactor, steam pressures went up in the reactors that were affected since the level of water reduced, making the hot fuel to be exposed. This exposure resulting in temperatures that led to zirconium fuel cladding reacting with steam and producing a hydrogen-enriched atmosphere. Accordingly, when the operators in the reactor vented the vessels to reduce steam pressure in the reactor, the vented gases coming from the reactor finally went to other sections of the reactor building, and mixed with air in this building resulting in explosive mixtures. When fresh water supplies were finished, the operators opted to use sea water that they injected in the pressure vessels to ensure fuel cooling. Though this seems a logical measure, it did result to some concerns regarding its long use owing to the possibility for pressure vessel corrosion and probable impairment and heat transfer together with salt deposition occurring on the fuel. An important aspect of most of the nuclear reactors is their ability to “natural” has a cooling capacity in a situation of forced circulation. Further analysis of cooling supplies Though, in UK there we have gas-cooled nuclear rectors and not BWR, the safety rules on regarding the design of the nuclear plant and particularly regarding cooling supplies is one area that can be improved (Waker, 2005). It would be very prudent to reexamine the capability for the coolant replenishment, n case extreme conditions like that happened in Japan occurs to the plants in the UK, when extra supplies on the nuclear plants may be hindered for some duration. Safety plans could thereafter be revised where necessary. At the same time, safety plans on design the motor driven auxiliary of a nuclear plant has to be reexamined. According to the Office for Nuclear Regulation (2011) heat sink normally built for post trip cooling system has to be provided for the essential services water system. This will provide an effective cooling system. According to Office for Nuclear Regulation (2011) the UK gas cooled nuclear reactors have got lower power densities, though they have bigger thermal capacities compared to water cooled nuclear reactors which have a natural cooling capacities that give longer durations for correction action. More so, the Health Safety Executive (2003) report shows that, they have a lower requirement for venting when loss of cooling occurs, and do not generate concentrations of hydrogen that is supposed to come from fuel cladding overheating. Owing to this observation, the UK nuclear plants should reexamine the need for, and where required the capability to provide a long withstanding coolant supplies to the nuclear plants in the country, in case a harsh off-site disruption happens. This is particularly true in a case where an on-site supplies or bigger off-site capacity is required. Conclusion From the discussion in this paper, it has to be understood that to attain sustained high standards of nuclear safety, countries have to follow the principle of “continuous improvement.” Indeed, this principle is outlined in the UK nuclear regulations, whereby there is constant requirement for the nuclear designers as well as the operators so as to reduce nuclear risks as much as practicable possible. This is outlined by the need for detailed regular appraisals of safety to look for more improvements. The Fukushima accident underlines the fact the no matter how good the levels of nuclear design and successive operations are, need for improvement should not stop. Endeavoring to learn from accidents and new knowledge both national and international has to be a basic aspect of safety practices of the UK nuclear industry. Bibliography Health Safety Executive (2003): Literature Review on the Perceived Benefits and Disadvnages of UK safety Case Regimes: Retrieved on 18/9/2011 from: http://www.hse.gov.uk/research/misc/sc402083.pdf NISA (2011): NISA briefing, Seismic Damage Information (12th Release), 12 March 2011, Retrieved on 18/9/2011 from: http://www.nisa.meti.go.jp/english/. Office for Nuclear Regulation (2011): Japanese earthquake and tsunami: Implications for the UK Nuclear Industry, Interim Report: HM Chief Inspector of Nuclear Installations: Retrieved on 18/9/2011 from: http://www.hse.gov.uk/nuclear/fukushima/interim-report.pdf Office for Nuclear Regualtion (2011a): European Council “Stress Tests” for UK Nuclear Power Plants National Progress Report:http://www.hse.gov.uk/nuclear/fukushima/stress-tests.pdf Okimoto, D , Hanson, A, Marvel, A (2011): The nuclear crisis in Japan. (March 2011). Retrieved on 18/9/2011 from: http://iis-db.stanford.edu/evnts/6615/March21_JapanSeminar.pdf. TEPCO press release (2011): Results of the investigation regarding tsunami arrived in Fukushima Dai-ichi Nuclear Power Station and Fukushima Power Station. Waker , C (2005): Nuclear Safety Directorate-Business Management system:http://www.hse.gov.uk/foi/internalops/nsd/tech_asst_guides/tast051.pdf World Nuclear Association (2011): Safety of Nuclear Power Reactors: Retrieved on 18/9/2011 from: http://www.world-nuclear.org/info/inf06.html Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Japanese Earthquake and Tsunami: Fukushima Research Paper”, n.d.)
Japanese Earthquake and Tsunami: Fukushima Research Paper. Retrieved from https://studentshare.org/environmental-studies/1756782-safety-cases-nuclear-industry
(Japanese Earthquake and Tsunami: Fukushima Research Paper)
Japanese Earthquake and Tsunami: Fukushima Research Paper. https://studentshare.org/environmental-studies/1756782-safety-cases-nuclear-industry.
“Japanese Earthquake and Tsunami: Fukushima Research Paper”, n.d. https://studentshare.org/environmental-studies/1756782-safety-cases-nuclear-industry.
  • Cited: 0 times

CHECK THESE SAMPLES OF Japanese Earthquake and Tsunami: Fukushima

Fukushima Nuclear Plant Explosion

The path from Fukushima: short and medium term impacts of the reactor damage caused by the Japan earthquake and tsunami on Japan's electricity systems, http://www.... After the Deluge, Short and medium term impacts of the reactor damage caused by the Japan earthquake and tsunami, http://www.... The immediate reason, or how the earthquake and the tsunami led to the disaster in the nuclear plant is identified and analyzed in the study.... The immediate reason, or how the earthquake and the tsunami led to the disaster in the nuclear plant is identified and analyzed in the study....
1 Pages (250 words) Essay

Who should be responsible for the Japan explosive hydrogen gas

Impacts on nuclear plants As a result of the high magnitude earthquake, Japan's nuclear power plants including fukushima I, fukushima II, Tokai nuclear power stations, and Onagawa Nuclear Power Plant containing eleven reactors were automatically shut down.... The diesel backup power systems of the fukushima I and II nuclear power plants were destroyed when the Tsunami waves overtopped seawalls (Lijaz).... It led to other severe issues including radioactive leakage and three large explosions at fukushima I....
5 Pages (1250 words) Essay

Lower Divison Capstone

Lower Division Capstone 29-10-11 Lower Division Capstone Part 1: The new chief executive of Versace, Gian Giacomo Ferrari, stated his desire of increasing the Company's focus on manufacturing Luxury fashion watches and jewellery, at the Baselworld watch fair held in March last year.... hellip; Furthermore, he stated that he wishes to do this by introducing a new line of Versace Luxury watches till the end of 2010....
4 Pages (1000 words) Essay

The Effects of Natural Disasters on the Economy

Japan's 2011 earthquake and tsunami :Economic Effects and Implications for the United States.... The fukushima disaster in Japan In 2011, the economy of Japan experienced a shake up after the nine-magnitude earthquake accompanied by tsunami hit this major economy.... Other than population displacement, there was also air contamination caused by leakage at the fukushima plant that specializes in nuclear energy production.... According records, eleven out of the fifty nuclear power stations felt the impact of the tsunami and the earthquakes meaning that the electricity production capacity dropped significantly and has remained at this level ever since....
3 Pages (750 words) Essay

The Tsunami that Devastated Japan

Days after the earthquake and tsunami, the survivors went back to their homes to look through the rubbles and debris, desperate to find some things which they can still salvage.... A major explosion hit a petrochemical plant in Sendai and in northeastern fukushima prefecture, a dam burst which swept away hundreds of homes.... The fukushima power plant was damaged by the huge floods which resulted in a nuclear disaster in Japan.... The author describes the tsunami which caused immense damage to Japan....
1 Pages (250 words) Essay

Nuke Evacuation in Fukushima

As Japan faced the danger of a nuclear disaster in the wake of a dreadful earthquake and tsunami, several organizations and news agencies monitored and gave impartial assessment of the state of affairs at Japan's nuclear facilities.... … As Japan faced the danger of a nuclear disaster in the wake of a dreadful earthquake and tsunami, several organizations and news agencies monitored and gave impartial assessment of the state of affairs at Japan's nuclear facilities....
1 Pages (250 words) Article

Comparison and Hurricanes

In comparison with the Japanese Tohoku earthquake and tsunami, the effects were far more devastating compared to Hurricane Sandy.... Over and above this, the tsunami had affected the nuclear power plant in fukushima causing a meltdown.... Moreover, the timing of the early warning system was late in conveying the threat of the tsunami in time following the massive earthquake.... To this effect, the sea walls built were only 25 feet in length since the government did not anticipate that any future tsunami would rise as high as 30 feet....
2 Pages (500 words) Essay

International Finance

The first section highlights how General Electric suffered adversely because of the 2011 crisis in Japan that involved an earthquake, tsunami, and nuclear radiation.... Under this section, the essay will use General Electric, which is an American MNE operating in Japan as the case study to investigate why the company decided to venture into the japanese market....
7 Pages (1750 words) Essay
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us