The paper "Advanced Glazing Calculator Techniques" is a great example of a research proposal on environmental studies.Assumption is that the height from the bottom of all windows to the eaves is 2200 mm. So the P/H value is 450/2200 = 0.2 Due to the fact that not all the P/H values and their respective Es values have been included in the table, interpolation was used to obtain the required values…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER94.8% of users find it useful

Extract of sample "Advanced Glazing Calculator Techniques"

PART 1: MANUAL CALCULATION STEP 1 Since the house is in climate zone 5 the conductance constant Cu is 13.464 (13.5) as seen from table 3.12.2.1. The house has a floor that is in direct contact with the ground and the air movement is standard. The solar heat gain constant for the house as obtained from table 3.12.2.1 is 0.122 Allowed solar heat gain =Area x CSHGC Therefore the solar heat gain allowance = 0.123X300 = 36.9 STEP 2 In this case the assumption is that the height from the bottom of all windows to the eaves is 2200 mm. So the P/H value is 450/2200 = 0.2 The P/H is used to locate the appropriate Ew value in the table. Due to the fact that not all the P/H values and there respective Es values have been included in the table ,interpolation was used to obtain the required values. The Ew values were as follows Ew1 value for A1= 0.78 Ew2 value for A2 = 1.56 Ew3 value for A3 =0.7 Ew4 value for A4 = 0.19 [(A1 x U1) + (A2 x U2) + …] / [(A1 x SHGC1 x Ew1) + (A2 x SHGC2 x Ew2) + …] = Aggregate Conductance {(42x7.9)+(8.4x7.9)+(16.8.x7.9)+(6x7.9)}/{(42x0.81x0.78)+(8.4x0.81x1.56)+(16.8x0.81x0.7)+(6x0.81x0.19)} = 378.28/47.59 = 7.94 This aggregate conductance value of 7.94 does not exceed the allowance of 13.5 and therefore complies. STEP 3 From the table for summer exposure factors it are obtained for the different glazing areas. The P/H is used to locate the appropriate Es value in the table. Due to the fact that not all the P/H values and there respective Es values have been included in the table interpolation was used to obtain the required values. The Es values were as follows ES1 value for A1= ES1=1.6 ES2 value for A2 = 0.38 ES3 value for A3 =1.1 ES4 value for A4 = 0.43 [(A1 x SHGC2 x Es1) + (A2 x SHGC2 x Es2) + (A3 x SHGC3 x Es3) +(A4 x SHGC4 x Es4)] = Aggregate solar heat gain {(42x0.81x1.06) + (8.4x0.81x0.38)+(16.8x0.81x1.1)+(6x0.81x0.43)} =55.71 This aggregate solar heat gain value of 55.70 does exceeds the allowance of 36.9 and therefore there is no compliance. PART 2: CALCULATOR Climate zone – The input climate zone is a cell where the appropriate BCA climate zone was entered and in this case the climate zone was taken to be 3. After entering the climate zone and the air movement was entered as standard while the floor type was given as direct contact. After input this details the calculator automatically gave the conductance as – and solar heat gain constants for the climate zone as --- Storey – in this cell the storey was entered as 1 Floor area – area was given as 300m2 all of which was direct contact type. It should also be noted that while the area is being entered the units are not supposed to be entered as this is automatically done when the numerical value has been entered. Conductance and Solar Heat Gain constants and allowances - this cells did not require the entering of any data as there was automatic change of the constants after selecting the climate zone, the type of floor and the air movement level. There was also automatic field change when the floor and type of air movement had been given. Details for Glazing elements ID - the calculator has a default list of numbers ranging from 1 to 40. The numbers that are visible is determined by the number of rows which has been chosen to be displayed in glazing element. In the current case the number selected was 4. Description – this gives the desired description for the glazing element. In case for description were Area1, Area2, Area3 and Area4. Facing sector – this gives information about the direction where the glazing element is facing. The eight sectors are available for choosing in a drop down list. In this case for sectors were used including West, South, North and East. Height, width, area – Usually when there are rectangular glazing elements the description is given by height and width these being the dimensions of the outside frame. When the input include the width and the height the inputting of the area is not a necessity. In the case where a larger area is input that the one that results from the dimensions the large area takes precedence. In the current example the elements were identical and thus they were grouped together. This is also applicable in a situation where the element areas are not in rectangular form. Performance Glazing Total U-Value and Glazing SHGC – these are inputs that are necessary in the spread sheet and usually are obtained from the manufacturer. The total U value which used was 7.9 while for the case of glazing SHGC the value used was 0.81 and 0.65. Shading Shading P – this value is given by the horizontal distance in metres from the glass face up to the shadow casting edge of the shading projection. In this case there was the P value was the eave measurement of 0.45m. Shading H – this is a distance measured from the glazing element base to the shadow casting edge of the projections like the eaves and gutter. In this case the H value used was either 2.2m or 1.6m depending on the height of the elements. Calculation data The use has no access to the cells that show the values in use when calculating solar heat gain and conductance of each of the glazing elements. These values include P/H value that is calculated from the P and H values. The exposure factors (Es or Ew) and Es/Ew are also calculated and displayed. It should be noted that the three values can only be viewed one at a time through making appropriate selection. Area used is also displayed and it is the product of height and with or any area that is given in the area column, with the preference being the larger area. Calculated outcomes U x area / winter access (Conductance) – This is where there is automatic calculation of the conductance of the various glazing elements. Element share of % of allowance used - This field is can be useful when understood as it comes in handy when optimizing the design. These are two percentages which are separated by “of”. The first figure gives the contribution the individual glazing element towards the aggregate conductance. Using this value it is easy for the user to identify the glazing element that has the largest impact. The second value is a comparison of aggregate performance and the conductance allowance. SHGC x Es x area (Solar heat gain) - This gives the automatic calculation of the solar heat gain of each glazing element. Element share of % of allowance used - The information given here is similar to the conductance details only that it is now based on the solar heat gain outcome. Compliance indicator – the result of whether the design meets the desired standards is given in the table which is below outcomes calculated. If there is a tick it means the result is YES while a cross stands for a NO. Reference ABCB (2011) Energy Efficiency Glazing Provisions for BCA Volume Two. Changes Introduced in BCA 2010 and Advanced Glazing Calculator Techniques. Read More

CHECK THESE SAMPLES OF Advanced Glazing Calculator Techniques

Inventory Management in Volga Glasses

The company uses elegant IT techniques to manage that smoothness.... The paper "Inventory Management in Volga Glasses" discusses that companies have to pay attention to develop more detailed market research which can estimate the nature of the supply chain in near future and can help develop their new IT strategies for the upcoming future....
6 Pages (1500 words) Term Paper

Klear View Double Glazing System Development Analysis

The analysis is based on a decision support system that was developed for the client using the spreadsheet software, Microsoft Excel 2007.... The main objective with which the system was developed was to display the powers provided with the help of computer-based systems to solve business problems....
6 Pages (1500 words) Term Paper

The Relationship Between Contribution and Profit Before Interest and Tax

The paper describes the two broad financing options available for any company that is Equity and Debt Financing.... Equity Finance is to raise finance by issuing shares, rights issue or by utilizing existing retained earnings of a company.... Finance is gathered by all such modes and then it is used upon in profitable ventures....
20 Pages (5000 words) Statistics Project

Managing Financial Resources and Divisions

This paper under the title "Managing Financial Resources and Divisions" focuses on the fact that, for instance, the company for which you are a senior accountant has recently won a major government contract to supply equipment to the health service and it is the biggest contract ever won by them....
16 Pages (4000 words) Assignment

Digital Image Processing Techniques

This report "Digital Image Processing techniques" discusses techniques that can be successfully used to delineate vegetation cover.... Thus the reliability of image processing techniques is sufficiently established.... The examples presented above clearly show that vegetative cover versus nonvegetative cover can easily be recognized using an NDVI classification....
8 Pages (2000 words) Report

Accounting and Finance for Managers

This paper discusses various accounting activities with respect to practical scenarios to enhance the knowledge of the managers.... The focus of the paper has been mainly related to ratio analysis, budgeting and project evaluation with respect to capital budgeting.... .... ... ... In addition, the project has also focussed on the relevance of cash flow projection in an evaluation of an investment outlay over profit projection....
11 Pages (2750 words) Essay

Improving Energy Consumption of Existing Buildings in Shanghai

This research paper "Improving Energy Consumption of Existing Buildings in Shanghai" comes up with various ways and suggestions to optimize energy consumption that is aligned towards cost minimization.... To achieve this, the project selected a medium-size building in Shanghai China.... .... ... ...
14 Pages (3500 words) Research Paper

The Steps on How to Calculate GPA

This work called The Steps on How to Calculate GPA" describes what actions to carry out concerning your academic positioning.... The author shows how to help or how to get your GPA in high school, which will help you decide if you still need to catch up.... ... ... ... Academic life is indeed demanding....
23 Pages (5750 words) Assignment
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us